2、請使(shi)用三(san)插(有(you)接地(di))插座(zuo),機上(shang)的接(jie)地螺(luo)釘要(yao)妥善(shan)接地(di),否則(ze)用💫測(ce)電筆(bi)測機(ji)殼将(jiang)有帶(dai)電現(xian)象,這(zhe)是由(you)于分(fen)布電(dian)容感(gan)應電(dian)引起(qi)的,屬(shu)正常(chang)現象(xiang),可通(tong)過接(jie)地線(xian)消💞除(chu)。如果(guo)機殼(ke)嚴✋重(zhong)漏電(dian),測絕(jue)緣👯🏾♂️電(dian)阻小(xiao)于2MΩ,可(ke)👽能是(shi)絕緣(yuan)🛌🏻層已(yi)受潮(chao)或線(xian)路與(yu)~機殼(ke)短路(lu),應查(cha)明原(yuan)😘因排(pai)除故(gu)障後(hou)再使(shi)用。
3、0.5 ~ 1.5KVA 小(xiao)功率(lü)穩壓(ya)器使(shi)用保(bao)險絲(si)作過(guo)流短(duan)路保(bao)護之(zhi)用,2 ~ 40KVA穩(wen)壓器(qi)🙈作用(yong)💌DZ47斷路(lu)器作(zuo)過流(liu)、短路(lu)保護(hu)之用(yong),如保(bao)險絲(si)經🤑常(chang)熔斷(duan)或斷(duan)路器(qi)經常(chang)跳閘(zha),應檢(jian)查用(yong)電是(shi)是💞否(fou)過大(da)。
4、當輸(shu)出電(dian)壓超(chao)過保(bao)護值(zhi)時(出(chu)廠時(shi)相電(dian)壓保(bao)護值(zhi)調整(zheng)爲250V±5V),穩(wen)壓電(dian)源自(zi)動保(bao)護,切(qie)斷穩(wen)壓電(dian)源輸(shu)出電(dian)壓,同(tong)💘時過(guo)😍壓指(zhi)示燈(deng)亮,用(yong)戶應(ying)立即(ji)關機(ji)檢查(cha)電網(wang)電壓(ya)或者(zhe)穩壓(ya)。如穩(wen)壓器(qi)發生(sheng)自動(dong)斷👹電(dian)(有輸(shu)入無(wu)💘輸出(chu)),應檢(jian)查市(shi)電電(dian)👩🏽🐰👩🏿壓是(shi)否高(gao)于28OV。若(ruo)低于(yu)280V 應檢(jian)查穩(wen)💁🏼♀️壓器(qi)是否(fou)發生(sheng)故障(zhang)。待查(cha)明原(yuan)因後(hou)再使(shi)用。
5、若(ruo)穩壓(ya)器輸(shu)出電(dian)壓偏(pian)離220V較(jiao)多,請(qing)調節(jie)控制(zhi)闆上(shang)電🙉位(wei)器至(zhi)輸出(chu)💁🏼♀️電壓(ya)正常(chang)(輸入(ru)電壓(ya)達不(bu)到穩(wen)壓範(fan)圍的(de)不能(neng)調節(jie))。
6、當市(shi)電電(dian)壓經(jing)常在(zai)穩壓(ya)器輸(shu)入電(dian)壓下(xia)限(<150V)或(huo)上限(xian)(>260V) 時,限(xian)位微(wei)動開(kai)關經(jing)常受(shou)碰觸(chu),易發(fa)生控(kong)制失(shi)靈。這(zhe)時穩(wen)壓器(qi)不能(neng)調壓(ya)或隻(zhi)能調(diao)高(或(huo)隻能(neng)調低(di)),應先(xian)檢查(cha)微動(dong)開關(guan)是否(fou)損壞(huai)。
7、請保(bao)持機(ji)内清(qing)潔,灰(hui)塵會(hui)阻礙(ai)齒輪(lun)之轉(zhuan)動、影(ying)響輸(shu)出電(dian)💑🏾壓精(jing)度。請(qing)及時(shi)清理(li)和維(wei)護線(xian)圈接(jie)觸面(mian)清潔(jie)。碳刷(shua)🧑🏻❤️🧑🏼磨損(sun)嚴重(zhong)時應(ying)調整(zheng)壓力(li),以免(mian)碳刷(shua)和線(xian)圈接(jie)😁觸面(mian)跳火(huo)。碳刷(shua)長度(du)不足(zu)2mm時應(ying)予以(yi)更換(huan)。線圈(quan)平面(mian)跳火(huo)被燒(shao)黑時(shi)應用(yong)細砂(sha)紙予(yu)以打(da)光。
8、三(san)相穩(wen)壓器(qi)輸入(ru)端必(bi)須接(jie)下零(ling)線(中(zhong)線),否(fou)則穩(wen)壓器(qi)無法(fa)正常(chang)負載(zai)工作(zuo),并将(jiang)會損(sun)壞穩(wen)壓器(qi)和用(yong)電設(she)備。切(qie)勿用(yong)地線(xian)替代(dai)零✡️線(xian)使用(yong)(但是(shi)零地(di)線可(ke)以并(bing)聯在(zai)一起(qi)),零線(xian)不得(de)接入(ru)保險(xian)絲。
9、穩(wen)壓器(qi)輸出(chu)電壓(ya)低于(yu)額定(ding)電壓(ya)(220V或三(san)相380V)時(shi),應檢(jian)查輸(shu)入電(dian)壓🤑是(shi)否過(guo)低。當(dang)空載(zai)時達(da)到額(e)定電(dian)壓而(er)負載(zai)時輸(shu)出低(di)于額(e)定電(dian)壓,這(zhe)是由(you)于輸(shu)入線(xian)路載(zai)面太(tai)小,或(huo)🙉負載(zai)端超(chao)過穩(wen)壓器(qi)額定(ding)容量(liang)👽範圍(wei),負載(zai)時線(xian)路壓(ya)降太(tai)大,使(shi)用輸(shu)入電(dian)壓低(di)于穩(wen)壓器(qi)調節(jie)範圍(wei)下限(xian),這時(shi)🚶🏾♀️➡️應更(geng)換較(jiao)粗🙂↔️的(de)輸入(ru)導線(xian)😮💨或是(shi)産品(pin)容量(liang)加大(da)。
10、當單(dan)台負(fu)載功(gong)率較(jiao)大(如(ru)空調(diao)等),而(er)輸入(ru)線路(lu)較長(zhang),載面(mian)又不(bu)足時(shi),負載(zai)工作(zuo)時電(dian)壓嚴(yan)重降(jiang)低,可(ke)能使(shi)用負(fu)載難(nan)以啓(qi)動;當(dang)👨🦰負載(zai)工作(zuo)時又(you)暫時(shi)停機(ji),易發(fa)生輸(shu)出瞬(shun)間過(guo)壓斷(duan)電,如(ru)發生(sheng)🔞這樣(yang)的現(xian)象,并(bing)非穩(wen)🧑🏾🎄壓器(qi)故障(zhang),應改(gai)善輸(shu)入線(xian)路(線(xian)🏊🏿♀️路加(jia)粗,盡(jin)量縮(suo)短輸(shu)入線(xian)長度(du),以減(jian)少線(xian)路中(zhong)壓降(jiang))。
11、當穩(wen)壓器(qi)輸出(chu)電壓(ya)嚴重(zhong)偏離(li)220V時,應(ying)檢查(cha)①輸入(ru)電壓(ya)👽是否(fou)穩壓(ya)範圍(wei)内;②電(dian)機齒(chi)輪是(shi)否嚴(yan)重磨(mo)損,轉(zhuan)動是(shi)否靈(ling)活;③限(xian)位開(kai)關是(shi)否受(shou)損:④線(xian)圈平(ping)面是(shi)否光(guang)滑;⑤控(kong)制闆(pan)有無(wu)損壞(huai)。